Case study: Evaluating comfort indexes in line with international standards

  • 作家相片: Paolo Casula
    Paolo Casula
  • 2024年6月12日
  • 讀畢需時 1 分鐘

已更新:5月29日


ree

Figure 1 illustrates the HVAC performance under following specified key parameters:


> 2 air inlets at the ceiling across the entire width of the room:

T=20 C, 2 Kg/s

> 3 air outlets located in the rear wall (red taps)

> 2 diabatic walls, facing the street, with assigned transmittance

> External air temperature T=0 C

> People surface temperature T=37 C


ree

Figure 1: HVAC performance of the Courtroom


Notably, on the rear side, the presence of over 20 individuals leads to improved heating conditions and a higher temperature. However, the presence of glass partition walls poses an obstacle, hindering temperature uniformity, as evident in the vertical section displaying the temperature map.


Towards the front of the room, a distinct temperature stratification can be observed. This stratification is reflected in a similar pattern within the heat flux map along the external wall.


ree

Figure 2: Computed thermal comfort values


Figure 2 provides an overview of the Comfort Indexes PMV & PPD, along with the computed indexes within the two volumes depicted in the render.



 
 
 